Simpson 260® Series 5

Analog - VOM

Volt-Ohm-Milliammeter

This is the base model of the Simpson 260-5 series. No mirrored dial or overload protection.

All improvements over the previous series are inside. This model takes the banana jack type test leads.

 Like the Simpson 260-5P, The 260-5 does not show anything about a Taut Band Suspension dial.

Controls include: Ohms zero adjustment, AC - DC - Select, a 12 position Function / Range

selector switch, and eight recessed probe jacks. 

The back of the case has an "adapter lock" for use with "Add-A-Tester" accessories.

The printed circuit boards can now withstand higher voltages than previous models.

The batteries can be installed without taking the whole unit apart. 

More inside views linked below.

The batteries used in this model are a single "D" cell, plus four "AA" batteries, there are two "AA"

below the "D" and one "AA" on each side.  The batteries can be installed without 

doing anything but removing the back of the case.

Case Size: 5¼ " x 7 " x 3"  -  Weight: 3 Pounds

The Adjust-A-View handle can also support the meter in a sloping position for viewing.

Simpson 260 Series 5 Specifications

DC VOLTAGE

Ranges 250mV, 1V, 2.5V, 10V ,25V, 50V, 250V, 500V, 1000V

Accuracy 2% of full scale * Sensitivity 20K per volt

AC VOLTAGE

Ranges 2.5V, 10V, 25V, 50V, 250V, 500V, 1000V

Accuracy 3% of full scale * Sensitivity 5K per volt

Rated Circuit-To-Ground Voltage 1000V (AC or DC) max.

DECIBEL

5 Ranges -20 to +50dB * Reference 0dB= 1mW into 600Ω

DC CURRENT

Ranges 50μA, 1mA, 10mA, l00mA, 500mA, 10A

Accuracy 1.5% full scale 5OμA, 2.0% of full scale, all other

Voltage Drop: (Nominal) 250mV on 50μA , 1mA; 255mV on 10mA , 10A; 300mV on 100mA, 500mV on 500mA

RESISTANCE

Ranges Rx 1, Rx 100, Rx 10K

Accuracy 2.5° of arc on Rx1, 2.0° of arc on other

Maximum Indication 0-2KΩ, 0-200Ω, 0-20MΩ

 

Back To Downloads                                                      Back To Main Page