Simpson 260® Series 7P

Analog - VOM

Volt-Ohm-Milliammeter

Simpson Catalog Number Unknown

The front on the Simpson 260 Series 7P changes from the Series 6, by the addition of a "off / transit"

position on the AC/DC switch. The output jack is also marked as 350 VDC Max.

New for the Simpson 260-7P is the size of the meter cover.

While the glass is the same size as always the cover is now 5 " x 3 ¾ " instead of 5 " x 4 ".

The 260 Series 7P has the three Amp-Clamp scales.

Controls include: Ohms zero adjustment, Off - AC - DC Voltage selector switch,

and a 12 position Function / Range selector switch.

The eight recessed probe jacks are now the "Reverse-Banana" type for safety.

The white overload reset button is just to the left of the Simpson logo.

Starting with the 260 Series 7 and the 270 Series 5, the 1000 Volts to Ground rating is engraved

in or printed on to the face, just below the model number.

The rear case has warnings and safety tips molded onto the back.

More inside views linked below.

This model uses the NEDA 13 F "D" cell and NEDA 1604A (9 Volt) batteries combination.

The 260-7P has the separate battery / fuse cover to allow you to change the batteries and fuses

without removing the entire back cover.

Case Size: 5¼ " x 7 " x 3"  -  Weight: 3 Pounds

The Adjust-A-View handle can also support the meter in a sloping position for viewing.

Simpson 260-7P Specifications

DC VOLTAGE

Ranges: 250mV, 1V, 2.5V, 10V, 50V, 250V, 500V, 1000V

Accuracy 2% of full scale * Sensitivity 20K per volt

AC VOLTAGE

Ranges 2.5V, 10V, 50V, 250V, 500V, 1000V

Accuracy 3% of full scale * Sensitivity 5K per volt

Rated Circuit-To-Ground Voltage 1000V (AC or DC) max.

DECIBEL

5 Ranges -20 to +50dB * Reference 0dB= 1mW into 600Ω

DC CURRENT

Ranges 50μA, 1mA, 10mA, l00mA, 500mA, 10A

Accuracy 1.5% full scale 5OμA, 2.0% of full scale, all other

Voltage Drop: (Nominal) 250mV on 50μA , 1mA; 255mV on 10mA , 10A; 300mV on 100mA, 500mV on 500mA

RESISTANCE

Ranges Rx 1, Rx 100, Rx 10K

Accuracy 2.5° of arc on Rx1, 2.0° of arc on other

Maximum Indication 0-2KΩ, 0-200Ω, 0-20MΩ