Simpson 160®
Handi - VOM
Volt-Ohm-Milliammeter
This model ships with both batteries, probe set, and an operators manual.
The Simpson 160 has Taut Band Suspension and a mirrored 100 degree dial to eliminate parallax errors.
Probe set used: Simpson Catalog Number 02055.
Controls include: Ohms adjustment, DC Voltage polarity selector switch, and a
20 position Function / Range selector switch. Six recessed probe jacks.
To remove knob, remove back cover, rotate knob to 250 VDC position, and loosen
set screw through the small slot at the bottom of the clear front cover.
No fuses are used, protected from overload by internal circuits.
The back cover on this model is smooth, the 160 Run II is a matte finish.
More inside views linked below.
Uses two batteries, one 1.5 Volt AA and one 22.5 Volt Eveready 505 (NEDA 221)
Remove back cover and then metal bar and insert positive terminal up.
Size: 4 ⅝ " x 3 ¼ " x 1¾ " Weight: 12 Ounces
Simpson 160 Specifications
DC VOLTAGE
Ranges 250mV, 1V, 2.5V, 10V, 50V, 250V, 500V, 1000V
Accuracy 2% of full scale * Sensitivity 20K per volt
AC VOLTAGE
Ranges 2.5V, 10V, 50V, 250V, 500V, 1000V
Accuracy 3% of full scale * Sensitivity 5K /volt
Rated Circuit-To-Ground Voltage 1000V AC/DC Max.
DECIBEL
5 Ranges -20 to +50dB *
Reference 0dB= 1mW into 600ΩDC CURRENT
Ranges 50μA, 1mA, 10mA, 100mA, 250mA, 500mA
Accuracy 2% of full scale
Voltage Drop: (Nominal) 250 mV or 50 mV on 50μA, (2ranges) 50 mV, all others
RESISTANCE
Ranges Rx1, Rx10, Rx100, Rx1K, Rx10K
Accuracy 3° of arc
Maximum Indication 0-3K, 0-30K, 0-300K, 0-3M, 0-30M