Simpson 295

Amp-Clamp     Volt - Ammeter

The Simpson 295 Amp-Clamp ships with a manual and test leads.

No fuses or batteries are used in this model. The knob on the right side selects the voltage or

current range. the gray flipper on the left locks the reading.

 Size: 10 " x 2.7" x 1.4"    Weight: 14 Ounces

Simpson 295 Specifications

AC Current

Six Ranges

0-6, 0-15, 0-30, 0-50, 0-150, 0-300 RMS Amperes

Accuracy 3% of full scale at 60 HZ sine wave, with current conductor centered.

Temperature Error: Less than 1% of full scale between 15 C to 35 C

AC Voltage

Four Ranges

0-30, 0-150, 0-300, 0-600 RMS Volts

Accuracy 3% of full scale at 60 HZ sine wave.

Temperature Error: Less than 0.5% of full scale max, between 15 C to 35 C

 

Rated Circuit-To-Ground Voltage

600 Volts RMS Max.  (850 Volts Peak)

 